Reading
Read Measuring Value Block (Scan Tool Function 08)
Initiating "Read Measuring Value Block"
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
Indicated on display
Rapid data transfer Q
08 - Read Measuring Value Block
- Confirm input using the -Q- button.
Indicated on display
Read Measuring Value Block
Input display group number XXX
- Input display group number and press -Q- button to confirm input.
The selected measuring value block is now displayed in standard form.