Adapting SRI For Inspection Service Interval-1 (IN1) (Time In Days)
Adapting SRI For Inspection Service Interval-1 (IN1) (Time In Days)
This function is used to enter the time until the next inspection service 1 is due (see service schedule "Maintenance Service").
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- to select "Adaptation" function 10 and press -Q- button to confirm input.
Indicated on display
Adaptation Q
Insert channel number XX
- Press buttons -0- and -7- to insert channel 07.
- Press -Q- button to confirm input.
Indicated on display
Channel 7 Adaptation 11 ->
<-1 3->
The display shows the days remaining until the next inspection service 1 is due (in this example "11" indicates 110 days remaining).
NOTES:
- Values can only be entered in increments of 10 days. Therefore the display shows blocks of 10 days.
- If the instrument cluster must be replaced, observe notes. Input Values For Instrument Cluster Replacement
- When using the scan tool keypad, only the direct input method can be used.
- If an incorrect value is input, the "adaptation" function 10 will be cancelled and must be initiated again.
- Press -> button.
Indicated on display
Channel 7 Adaptation 11
Input adaptation value XXXXX
- Input desired interval value using keypad on VAG1551, fill in leading digits with zeroes "0."
Example:
Specification: 360 days
Input value: 00036
Indicated on display
Channel 7 Adaptation 11 Q
Input adaptation value 00036
- Press -Q- button to confirm input.
Indicated on display
Channel 7 Adaptation 36 Q
<-1 3->
- Press -Q- button to confirm input.
Indicated on display
Channel 7 Adaptation 36 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display
Channel 7 Adaptation 36 ->
Changed value is stored
- Press -> button to end SRI adaptation.
Indicated on display
Rapid data transfer HELP
Select function XX