Display Group 004
NOTE:
- Values in display fields 2 and/or 3 can only be evaluated with idle air control valve is within tolerance at idle (display value 1). If the idle air control valve is not within tolerance after 1 minute waiting time, no learning takes place in display fields 2 and/or 3.
- Positive learning values show a greater learning value than in the basic setting: -N71- is further open.
- Negative learning values show a learning value that is less than in basic setting: -N71- is more closed.
Test table display group 004
NOTE: Display field 4 (shift inputs) can be used to recognize whether the components described below are recognized by the Engine Control Module (ECM) as switched on or off Display group 023 gives an exact description of the shift inputs.