Procedures







Insertion Depth Of Breather Sleeve
- Dimension -a- = 13 mm (0.51 in.)






Installation Position Of Magnet
- Replace clip when performing repairs.






Installation Position Of Locking Ring
(Differential removed for clearer illustration)
- The oil supply grooves (arrows) in the differential housing and locking ring must be aligned.






Determining Thickness Of Shim For Locking Ring






- Measure dimension -b- and determine shim from table.