Operation CHARM: Car repair manuals for everyone.

Setting SRI and Mileage



NOTE: Instrument cluster must be coded before setting if it was replaced.


- Press button -1- to select "Rapid data transfer" operating mode 1.

Indicated on display

Rapid data transfer HELP
Insert address ward XX


- Press buttons -1- and -7- to insert "Instrument Cluster" address word 17.

Indicated on display

Rapid data transfer Q
17- Instrument Cluster


- Press -Q- button to confirm input.

Indicated on display

Rapid data transfer
Scan Tool sends address word 17


After 5 seconds the display indicates a part number and the control module code.

4D0919033C4 Instrument cluster D03 -->
Coding 00262 WSC 06812


- Press -> button.

Indicated on display

Rapid data transfer Q
Select function XX


Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display

Rapid data transfer Q
10 - Adaptation


- Press -Q- button to confirm input.

Indicated on display

Adaptation
Insert channel number XX



SRI, oil change indicator, resetting (distance)


NOTE:
- Setting of service interval display must be done in kilometers. Therefore calculate the value from miles to kilometers. Multiply miles by 1.6 to convert to km.
- Adaptation number is for example only.
- Press buttons -0- and -5- to select channel 5.
- Press -0- button to confirm input.

Indicated on display

Channel 5 Adaptation 15 ->
<- 1 3 ->


- Advance through program with - button.

Indicated on display

Channel 5 Adaptation 15 Q
Input adaptation value XXXXX


- Input 5 digit adaptation value between 0 km (00000) and 15000 km (00015).

The value can be entered in steps of 1000 km
Example: 7500 mi/2000 km, therefore enter 00012.

Indicated on display

Channel 5 Adaptation 15 Q
Input adaptation value 00012


- Press -Q- button to confirm input.

Indicated on display

Channel 5 Adaptation 12 Q
<- 1 3 ->


- Press -Q- button to confirm input.

Indicated on display

Channel 5 Adaptation 12 Q
Store changed value?


- Press -Q- button to confirm input.

Indicated on display

Channel 5 Adaptation 12 Q
Changed value is stored


- Press - button to end coding.

Indicated on display

Rapid data transfer HELP
Select function XX


- Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display

Rapid data transfer Q
10 - Adaptation


- Press -Q- button to confirm input.

Indicated on display

Adaptation
Insert channel number XX



SRI, inspection indicator (In 1), resetting (distance)


NOTE: Setting of service interval display must be done in kilometers. Therefore calculate the value from miles to kilometers. Multiply miles by 1.6 to convert to km.


- Press buttons -0- and -6- to select channel 6.
- Press -Q- button to confirm input.

Indicated on display

Channel 6 Adaptation 30 ->
<- 1 3 ->


- Press - button to advance through program sequence.

Indicated on display

Channel 6 Adaptation 30 Q
Input adaptation value XXXXX


- Enter value between 0 km (00000) and 30000 km (00030).

The value can be entered in steps of 1000 km.

Example: 15000 mi/24000 km, therefore enter 00024.

- Press -Q- button to confirm input.

Indicated on display

Channel 6 Adaptation 24 Q
<- 1 3 ->


- Press -Q- button to confirm input.

Indicated on display

Channel 6 Adaptation 24 Q
Store changed value?


- Press -Q- button to confirm input.

Indicated on display

Channel 6 Adaptation 24 -->
Changed value is stored


- Press -> button to end coding.

Indicated on display

Rapid data transfer HELP
Select function XX


- Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display

Rapid data transfer Q
10 - Adaptation


- Press -Q- button to confirm input.

Indicated on display

Adaptation
Insert channel number XX


SRI, inspection indicator (In 1), resetting (time)

- Press button -0- and -7- to select channel 7.
- Press -Q- button to confirm input.

Indicated on display

Channel 7 Adaptation 36 -->
<- 1 3 ->


- Advance through program sequence with - button.

Indicated on display

Channel 7 Adaptation 36 Q
Input adaptation value XXXXX


- Enter adaptation value between 0 days (00000) and 360 days (00036). The value can be entered in steps of 10 days. Example: 360 days, therefore enter 00036.


NOTE: Inspection table, Replacing


- Press -0- button to confirm input.

Indicated on display

Channel 7 Adaptation 36 Q
<- 1 3 ->


- Press -Q- button to confirm input.

Indicated on display

Channel 7 Adaptation 36 Q
Store changed value?


- Press -Q- button to confirm input.

Indicated on display

Channel 7 Adaptation 36 ->
Changed value is stored


- Press - button to end coding.

Indicated on display

Rapid data transfer HELP
Select function XX


- Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display

Rapid data transfer Q
10 - Adaptation


- Press -Q- button to confirm input.

Indicated on display

Adaptation
Insert channel number XX


SRI, inspection indicator (In 2), resetting (time)

- Press button -0- and -8- to select channel 8.
- Press -Q- button to confirm input.

Indicated on display

Channel 8 Adaptation 66 -->
<- 1 3 ->


- Advance through program sequence with - button.

Indicated on display

Channel 8 Adaptation 66 Q
Input adaptation value XXXXX


- Enter Adaptation value between 0 days (00000) and 730 days (00073). The value can be entered in steps of 10 days. Example: 730 days, therefore enter 00073.

- Press -0- button to confirm input.

Indicated on display

Channel 8 Adaptation 73 Q
Store changed value?


- Press -Q- button to confirm input.

Indicated on display

Channel 8 Adaptation 73 Q
Changed value stored


- Press -> button to end coding.

Indicated on display

Rapid data transfer HELP
Select function XX


- Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display

Rapid data transfer Q
10 - Adaptation


- Press -Q- button to confirm input.

Indicated on display

Adaptation
Insert channel number XX