Adapting SRI After Replacing Instrument Cluster (Remaining Distance Until Next Service Inspection)
M.y. 1998 >
Adapting SRI After Replacing Instrument Cluster (Remaining Distance Until Next Service Inspection)
This function is used to adapt the remaining km until the next service inspection is due after the instrument cluster was replaced.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- to select "Adaptation" function 10 and press -Q- button to confirm input.
Indicated on display
Adaptation
Insert channel number XX
- Press buttons -1- and -1- to insert channel 11.
- Press -Q- button to confirm input.
Indicated on display
Channel 11 Adaptation 5 ->
<-1 3->
The display shows the kilometers remaining until the next inspection service is due (in this example "5" indicates 5000 km remaining).
NOTES:
- Values can only be entered in increments of 1000 km. Therefore the display shows units of 1000.
- In countries where speedometers are calibrated in miles, adjustments must still be made in kilometers. Therefore convert miles to kilometers (miles x 1.609 = kilometers) to get the required adaptation value.
- The value entered is counted down to 0 km.
- If the instrument cluster must be replaced, observe notes. Input Values For Instrument Cluster Replacement
- When using the scan tool keyboard, only the direct input method can be used.
- If an incorrect value is input, the "adaptation" function 10 will be cancelled and must be initiated again.
- Press -> button.
Indicated on display
Channel 11 Adaptation 0
Input adaptation value XXXXX
- Input desired interval value using keypad on VAG1551, fill in leading digits with zeroes "0."
Example:
Remaining km: 5000 km
Input value: 00005
Indicated on display
Channel 11 Adaptation 0 Q
Input adaptation value 00005
- Press -Q- button to confirm input.
Indicated on display
Channel 11 Adaptation 5 Q
<-1 3->
- Press -Q- button to confirm input.
Indicated on display
Channel 11 Adaptation 5 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display
Channel 11 Adaptation 5 ->
Changed value is stored
- Press -> button to end SRI adaptation.