Fuel Distance/Mileage Module: Service and Repair




Adaptation

Individual functions are called up by entering the appropriate adaptation channel numbers (listed in the adaptation table).


NOTE:
- Using measuring value blocks 10,11, 12 and 15, the values that need to be transferred to the new instrument cluster can be read out before replacement.
- Adaptation channels 42-44 (see measuring value blocks 13 and 14) do not need to be transferred when replacing instrument cluster, because they are adjusted by the factory for each new instrument cluster


Adaptation table:







Initiating "Adaptation" function 10

Indicated on display


Rapid data transfer HELP
Select function XX


- Press buttons -1- and -0- to select "Adaptation" function 10.
- Press -Q- button to confirm input.

Indicated on display


Rapid data transfer Q
10 - Adaptation


- Press -Q- button to confirm input.

Indicated on display:


Adaptation
Insert channel number XX


- Enter desired adaptation channel (adaptation table).
- Press -Q- button to confirm input.


NOTE: After changing an adaptation value or ending an adaptation channel, "Adaptation" function 10 must be performed again before selecting another adaptation channel.


Adaptation of total consumption quantity

Indicated on display


Rapid data transfer HELP
Select function XX


- Press -1- and -0- and confirm by pressing the -Q- button.

Indicated on display


Rapid data transfer Q
10 - Adaptation


- Press -Q- button to confirm input.

Indicated on display:


Adaptation
Insert channel number XX


- Press buttons -4- and -6-.
- Press -Q- button to confirm input.


NOTE:
- Indicated value must be transferred when replacing instrument cluster.
- The value indicated in liters does not represent actual consumption, but rather a calculation value for the Service Reminder Indicator (SRI) from various engine data.


Indicated on display:


Channel 46 Adaptation 300 ->
Consumption quantity in liters <-1 3->


- Press -> button.

Indicated on display:


Channel 46 Adaptation 300
Input adaptation value XXXXX


- Input the indicated value of the old instrument cluster into the new instrument cluster using the keypad of the scan tool, fill initial positions with "0."

Desired input value: 300 Liters
Keypad input: 00300

Indicated on display:


Channel 46 Adaptation 300 Q
Input adaptation value 00300


- Press -Q- button to confirm input.

Indicated on display:


Channel 46 Adaptation 300 Q
Consumption quantity in Liters <-1 3->


- Press -Q- button to confirm input.

Indicated on display:


Channel 46 Adaptation 300 Q
Store changed value?


- Press -Q- button to confirm input.

Indicated on display:


Channel 46 Adaptation 300 ->
Changed value is stored


- Conclude adaptation of total consumption quantity by pressing the -> button.