With Manufacturer Scan Tool
Check DTC Memory (Function 02)
NOTE: Fault in formation displayed is not updated constantly, but rather only on starting On Board Diagnostic (OBD)/implementing function 05 "Erase DTC Memory".
- Switch on printer by pressing PRINT key (lamp in key lights)
Implementing function "02 - Check DTC Memory"
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press keys 0 and 2.
Indicated on display:
Rapid data transfer Q
02 - check DTC Memory
- Confirm entry with Q key.
The number of stored faults appears on the display.
X faults detected ->
The stored faults are consecutively displayed and printed out.
- Consult Diagnostic Trouble Code (DTC) table with fault printed out and eliminate fault.
In the case of "No faults detected", program returns to start after pressing -> key.
No faults detected ->
Indicated on display:
Rapid data transfer HELP
Select function XX
If any other display appears:
- Erase DTC Memory (function 05).
- End Output (function 06).
- Switch off ignition and unplug diagnostic connector.