Ultrasonic Sensor: Service and Repair
Adaptation (Function 10)
The adaptation function can be used to carry out and store the following adjustment:
- The ultrasonic sensors can be adjusted to reduce their sensitivity level.
Performing adaptation (function 10)
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -1 - and -0-.
Indicated on display
Rapid data transfer Q
10 -Adaptation
- Confirm input with -Q- button.
Indicated on display
Adaptation
Feed in channel number XX
- Press buttons -0- and -1 -.
Indicated on display
Adaptation Q
Channel display 10
- Confirm input with -Q- button.
Indicated on display: the display will show the sensitivity level of the
sensors, e.g. 100%.
Channel 1 Adaptation 100 ->
Sensitivity in % < -1 3- >
NOTE: The max. sensitivity level for the ultrasonic sensors is 100% (factory setting). This can be reduced down as far as 50%.
- Press -> button.
Indicated on display
Channel 1 Adaptation 100
Enter adaptation value XXXXX
- Enter sensitivity level e.g. 75 % = 00075
Indicated on display
Channel 1 Adaptation 100 Q
Enter adaptation value 00075
- Confirm input with -Q- button.
Indicated on display
Channel 1 Adaptation 75 Q
Sensitivity in % < -13- >
- Confirm input with -Q- button.
Indicated on display
Channel 1 Adaptation 75 Q
Store changed value?
- Confirm input with -Q- button.
Indicated on display
Channel 1 Adaptation 75 ->
Changed value is stored
- Press -> button to terminate adaptation procedure for sensitivity level.
Indicated on display
Rapid data transfer HELP
Enter address word XX