With Manufacturer's Scan Tool
Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC), Checking
Special tools and workshop equipment required
- VAS 5051 Vehicle diagnostic, testing and information system
- VAS 5051/1 Adapter
Requirements
- Coolant temperature at least 80 degrees C.
Work sequence
- Connect vehicle diagnostic, testing and information system VAS 5051 and select vehicle system "01 - Engine electronics" in selection. Engine must be run at idle.
Display on VAS 5051:
- Under -1- select diagnostic function "04 - Basic setting".
Display on VAS 5051:
1. Enter display group
- Enter "043" for "display group number 043" in field -2- and confirm entry by pressing -Q- button.
Display on VAS 5051:
- Activate basic setting by pressing -A- button.
- Press accelerator and brake pedal simultaneously; engine speed increases to approx. 2300 rpm.
Conditions
- Accelerator and brake pedal pressed simultaneously, engine runs at approx. 2300 rpm.
- Check indication in display group -4-.
(Cont.)
If specification in display field 4 is not obtained:
- Perform test drive to free oxygen sensor from any possible residues and repeat test.
If specification in display field 4 is not obtained even after a test drive has been performed:
- Replace Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130-.