Operation CHARM: Car repair manuals for everyone.

Pinout Values and Diagnostic Parameters




Read Measuring Value Block (function 08)
- Initiate output Diagnostic Test Mode of instrument cluster, Initiating


Display on VAS5051:







- Select diagnostic function "08 - read measured value block" in selection -1-.


Display on VAS5051:







1 - Enter display group Max. input value = 255
- Enter desired display group number in button field -2-.
- Press -Q- button to confirm input.


Display on VAS5051:







1 - Display group X
2 - Display field 1
Display field 2
Display field 3
Display field 4


NOTE:
- If no display follows, a display field is not assigned.
- To switch to a different display group, proceed as follows:


Display group VAS5051 tester
higher Press s button.
Lower Press t button.

- Press "08 - Erase DTC Memory" to end function <- button.

Display group overview

Display group number Indicated on display
001 1 = Road speed km/h
2 = Engine speed (RPM)
3 = Oil pressure 2 < min
4 = Time h

002 1 = Trip odometer
2 = Fuel gauge 1
3 = Tank sensor Ohm
4 = Outside air temperature

003 1 = Engine coolant temperature ° C

010 1 = Channel 30
2 = Adaptation tank sensor
3 = Channel 9
4 = odometer mi

011 1 = Channel 4
2 = Language version
3 = Channel 3
4 = Consumption display

012 1 = Channel 40
2 = odometer since service mi
3 = Channel 41
4 = Time since service

013 1 = Channel 42
2 = Minimum value mi
3 = Channel 43
4 = Maximum value mi

014 1 = Channel 44
2 = Max. time interval
3 = Unassigned
4 = Unassigned

015 1 = Channel 45
2 = Oil quality
3 = Channel 46
4 = Total consumption quantity

050 1 = odometer mi
2 = Engine speed 1/RPM
3 = Oil temperature ° C
4 = Engine coolant temperature ° C

125 1 = Engine
2 = Transmission
3 = ABS
4 = ADR

126 1 =A/C

130 1 = Tire pressure
2 = Auxiliary heater
3 = Unassigned
4 = Parking assistance

140 1 = Radio
2 = Telephone
3 = Navigation
4 = Telematic (Tele-data-processing)

NOTE:
- If the instrument cluster is replaced, the data from display groups 010 to 015 must be printed out.
- Measuring value blocks 125 and 126 indicate the components that are part of the powertrain CAN-bus.
- Measuring value block 130 indicates the participants in the comfort system CAN-bus.
- Measuring value block 140 indicates the participants in the information CAN-bus.
- Display will always indicate the actual values obtained from senders and sensors. The values which appear on the instrument cluster are filtered and may be different.
- If the actual coolant temperature is between 80 °C and 100 °C, the instrument cluster always displays 90 °C.


Measuring value block 001







Measuring value block 002







Measuring value block 003







Measuring value block 010







Measuring value block 011







Measuring value block 012







Measuring value block 013







Measuring value block 014







Measuring value block 015







Measuring value block 050







Measuring value block 125







Measuring value block 126







Measuring value block 130







Measuring value block 140