Evaporative Emissions (EVAP) System Diagnostic Leak Test, Performing
Evaporative Emissions (EVAP) System Diagnostic Leak Test, Performing
Special tools, testers and auxiliary items required
- Vehicle Diagnostic, Testing and Information System VAS 5051 A with diagnostic cable VAS 5051/5A
NOTE:
- Secure all hose connections using hose clamps appropriate for the model type Parts catalog.
- Replace O-rings and gaskets when performing repair work.
Test conditions
- Parking brake is applied.
- Vehicles with manual transmission: Shift lever in neutral.
- Vehicles with automatic transmission: Selector lever in position "P" or "N".
- Engine running at idle.
- Electrical consumers switched off (Radiator fan must not run during test).
- Climate control switched off.
- Vehicle Diagnostic, Testing and Information System VAS 5051 A connected, On-board diagnostics and vehicle system "01 Engine electronics" selected.
- No faults in DTC memory.
- Intake air temperature less than 90 degrees C - Measuring value block 004, display field 4.
- Coolant temperature less than 95 degrees C - Measuring value block 004, display field 3.
- Throttle valve angle less than 10 degrees - Measuring value block 003, display field 3.
Test sequence
Display on VAS 5051 A:
- In selection -1-, click on diagnostic function "04 - Basic Setting".
Display on VAS 5051 A:
1. Enter display group
- Select function "071" in button field -2- for "display group number 071" and press Q to confirm input.
Display on VAS 5051 A:
- Check reading in display field -1-.
Specification: "Reed closed."
NOTE:
- If "Reed closed" is displayed, continue test.
- If the reading on the display shows "Reed open": Briefly open the cap of the fuel tank to relieve pressure - thereby the reed contact will close again.
- Activate basic setting by pressing button - A -.
- Check reading in display field -4-.
Specification: "Test ON"
The system test takes several minutes.
- Check reading in display field -4-.
Specification: "Syst.O.K."
The system is sealed, the test is ended.
- End function "04 - Basic setting" by pressing button.
Fault indication
If a malfunction was recognized during the system test, the malfunction is indicated afterward.
On VAS 5051 A display in display field - 4- -:
- In case of malfunction: Syst. n.O.K..
- Check readings of the diagnosis in display field -2-.
- "Small leak" or "Large leak"
- End function "04 - Basic setting" by pressing button.
If the system has recognized a small or large leak:
- Check fuel supply and tank ventilation systems for leaks.
- Afterwards, perform the leak diagnosis again.