Blower Motor: Service and Repair
Fresh Air Blower Control Module J126 And Fresh Air Blower V2, Removing And Installing
Removing
- Remove glove compartment.
- Disconnect connector - A -.
- Remove lower "A-pillar" trim.
- Loosen cable ties - B -.
- Remove bolts - A -.
- Pull air conditioner slightly to rear.
- Carefully fold back floor covering.
- Press noise insulation mat aside until rear bolt - C - is accessible.
- Remove bolts - C -.
- Push noise insulation mat aside and pull Fresh Air Blower V2 - D - out of air conditioner.
NOTE:
- The Fresh Air Blower V2 contains the Fresh Air Blower Control Module J126 as an integral component which cannot be replaced separately.
- When installing, pay attention to correct positioning of Fresh Air Blower V2 in air conditioner.
Installing
Install in reverse order.