Operation CHARM: Car repair manuals for everyone.

Secondary Air Injection Combination Valves, Checking for Function and Leaks






Secondary Air Injection Combination Valves, Checking for Function and Leaks

Special tools, testers and auxiliary items required

Hand Vacuum Pump (VAS 6213)

Procedure

Hose connections properly sealed.

- Remove affected secondary air injection combi-valve. Refer to => [ Secondary Air Injection Combination Valves ] Service and Repair.

- Connect Hand Vacuum Pump (VAS 6213) to vacuum connection - 1 - on secondary air injection combi-valve.





- Connect an appropriate assisting hose - 2 - to Secondary Air Injection (AIR) combi-valve.

- Blow into the assisting hose - 2 - using light pressure (do not use pressurized air).

Secondary Air Injection (AIR) combination valve must be closed, it must not be possible to blow through.

- Operate the hand vacuum pump.

The Secondary Air Injection (AIR) combination valve must open, it must be possible to blow through.

If secondary air injection combi-valve does not open:

- Replace affected Secondary Air Injection (AIR) combi-valve. Refer to => [ Secondary Air Injection Combination Valves ] Service and Repair.