Operation CHARM: Car repair manuals for everyone.

Procedures






Tail Pipes, Aligning

Procedure

Tightening specifications, refer to => [ Muffler Overview ] Muffler Overview.

- Check distance of the tail pipes at left and right to bumper:

Dimension - x - left = dimension - x - right.






Correct dimension "x" as follows if necessary:






- Loosen the brace threaded connection - arrow - between the exhaust pipes.

- Adjust the distance of the rear mufflers to each other.

- Tighten the threaded connection.

- Check tail pipe distances - y - and - z - to the bumper:






Dimension - y - = 17 to 19 mm.

Dimension - z - = 0 +/- 2 mm.

- If necessary, make sure the exhaust system is aligned free of tension. Refer to => [ Exhaust System, Installing ] Service and Repair.