Evaporative Purge Regulator Valve, Checking
Evaporative Purge Regulator Valve, Checking
Observe all safety precautions: => [ Safety Precautions ] Generic Scan Tool
View clean working conditions: => [ Clean Working Conditions ] Clean Working Conditions
Use only gold-plated terminals when servicing any component with gold-plated electrical harness connector terminals.
For wiring diagrams, component locations, and connector views, refer to the applicable wiring diagram.
Special tools, testers and auxiliary items required
• multimeter
• Wiring diagram.
Test requirements
• The Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) fuse OK.
• The ignition switched off.
• Voltage for the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) is supplied via the Motronic Engine Control Module (ECM) Power Supply Relay (J271).
Test procedure
- Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] Preliminary Check
Start diagnosis
- Remove the engine cover with air filter. Refer to appropriate service manual.
- Disconnect the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical harness connector - 1 -.
Checking internal resistance
- Using a multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) terminals 1 and 2 for resistance.
Specified value: 22.0 to 30.0 ohms.
If the specified value is not obtained:
- Replace the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80).
If the specification is obtained:
Checking voltage supply
- Using a multimeter, check the electrical harness connector terminal 1 to 2 for voltage.
- Operate the starter briefly.
Specified value: battery voltage.
If the specified value was not obtained:
- Using a multimeter, check the electrical harness connector terminal 1 for voltage.
- Operate the starter briefly.
Specified value: battery voltage.
If the specified value is not obtained:
- Check the wiring connection from the electrical harness connector terminal 1 to the Motronic Engine Control Module (ECM) Power Supply Relay (J271) terminal 2/87 for an open circuit.
- Check the electrical harness connector for damage, corrosion, loose or broken terminals.
- If necessary, repair the wiring connection.
If the specified value was obtained:
Check Ground (GND) activation
- Using a multimeter, check the electrical harness connector for voltage.
- Operate the starter briefly.
Specified value: battery voltage.
- Switch the ignition off.
If the specified value was not obtained:
If the manufacturers test box is being used, perform the following step.
- Install the test box.
If the manufacturers test box is not being used, perform the following step.
- Remove the Motronic Engine Control Module (ECM) (J623). Refer to appropriate service manual.
- Using a multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical connector terminal 2 to Motronic Engine Control Module (ECM) (J623) electrical connector T60 for an open circuit.
Specified value: 1.5 ohms max.
If the specification is not obtained:
- Check the wiring for a short circuit to Battery positive (+) or an open circuit.
- Check the electrical harness connector for damage, corrosion, loose or broken terminals.
- If necessary, repair the wiring connection.
If the specification was obtained:
- Replace the Motronic Engine Control Module (ECM) (J623). Refer to appropriate service manual.
- Install the engine cover with air filter. Refer to appropriate service manual.
Final procedures
After the repair work, the following work steps must be performed in the following sequence:
1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] Diagnostic Modes 01 - 09.
2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Modes 01 - 09.
3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] Readiness Code.