Operation CHARM: Car repair manuals for everyone.

DME System 2 (Code 2263)

Engine Management: Motronic Control Unit 2 (DME/EML 1.7):





1. With the engine at normal operating temperature disconnect the purge valve connector and connect a voltmeter between terminals 1 and 2 of the female side of the connector (X6122).
2. Start the engine a run at 1800 rpm for 60 seconds.

^ If the voltmeter cycles between battery and 0 volts and code 2263 is stored in Digital Motor Electronic (DME) memory, replace the purge valve.
^ If the voltmeter reads 0 volts continuously, go to step 3.
^ If the voltmeter reads battery voltage continuously, check or repair brown wire from terminal 2 of X6122 to terminal 36 of the DME control module harness connector for a short to ground. If a short to ground is not present, the DME control module is defective.

3. With the ignition switch "OFF", disconnect the DME control unit connector (X6020).
4. Connect a fused jumper between terminal 36 of harness connector X6020 and ground.
5. Connect a fused jumper between terminal 27 of harness connector X6020 and ground.
6. Turn the ignition switch to the "RUN" position, and measure the voltage at X6122.

^ If the voltmeter reads battery voltage, remove the fused jumpers. The DME control unit is defective.
^ If battery voltage is not present, remove the fused jumpers and check the wires for opens and the DME main relay for proper operation. Repair or replace as necessary.