Temperature Sensing Equipment
Correct climate control diagnosis requires an accurate and reliable temperature sensing device. A high quality analog thermometer or a digital pyrometer is recommended.
TYPICAL USE: A/C PERFORMANCE QUICK CHECK
Test conditions = 90 °F & 50% Humidity
- Note ambient temperature.
- Close all windows and doors.
- Engine speed = 1500 RPM.
- Blower speed = Medium.
- Temperature selector Maximum cooling.
- "Snowflake" button = A/C On.
- Let the engine run for approximately five minutes to stabilize the A/C system.
Expected result for a properly functioning system:
- Center vent discharge temperature = > 20 °F less than the ambient temperature.
DIS TEMPERATURE PROBE
The Diagnosis and Information System (DIS) tester is equipped with a temperature sensor cable, stored in the compartment at the rear of the tester. It can be used to measure the temperatures of liquids and gasses from -20° to +200 °C.
To use the DIS as a thermometer:
- Push "Measurement System" button on the DIS start screen..
- Push "Temperature C" button on the "Measuring System Multimeter" screen,
COOLING / HEAT GUN
To simulate testing temperatures, use the approved "Heating/Cooling Gun Kit."
Reference TSB 04 14 89.