61 20 503 Vehicle Battery-Closed-Circuit Current Monitoring
61 20 503 Vehicle Battery-Closed-Circuit Current Monitoring
Necessary preliminary tasks:
To access negative lead of battery, perform the necessary preliminary work described in Disconnecting negative battery cable.
Do not disconnect negative lead of battery.
Connect BMW diagnosis system.
Connect clip-on probe to negative lead of battery. The arrow on the current clamp must point towards the battery.
Measure closed-circuit current.