Fuel Pump Control Unit: Service and Repair
16 14 500 - Removing and installing or replacing control unit for electric fuel pump
Important!
Read and comply with notes on protection against electrostatic damage (ESD protection) 61 35 ... Notes on ESD Protection (Electro Static Discharge).
Necessary preliminary tasks:
- Raise luggage compartment floor trim
Release screws (1) and remove battery cover towards top.
Unlock plug connections (1) and disconnect.
Release nuts (2) and remove control unit.
(Internal nut must only be slackened).
Installation Note:
Tightening torque 16 14 1AZ 16 14 Fuel Pump.
Replacement:
- Carry out programming/coding Programming and Relearning