Operation CHARM: Car repair manuals for everyone.

Shift Solenoids Resistance Values

RESISTANCE VALUES

VCC Apply Solenoid at 20°C (68°F) 20-30 Ohms
VCC Apply Solenoid at 88°C (190°F) 23-50 Ohms


VCC MOD Solenoid at 20°C (68°F) 10-15 Ohms
VCC MOD Solenoid at 88°C (190°F) 11-25 Ohms

Shift "A" & "B" Solenoid at 20°C (68°F) 20-30 Ohms
Shift "A" & "B" Solenoid at 88°C (190°F) 23-50 Ohms

Temperature Switch (vehicles with Traction Control only) normally closed up to 156-164°C (313-327°F), then an open circuit and recloses on a temperature decrease at 149°C (300°F).