Troubleshooting Hints - Digital Cluster
PERFORM BEFORE BEGINNING SYSTEM DIAGNOSIS:1. Check I/P Fuse Block Fuses 1D, 3E, 9C, 1A and 5A by visual inspection.
2. Check Relay Center Fuse 8 by visual inspection.
3. If more than one indicator or gage is out, check common power and ground inputs.
4. Before component replacement, check for poor connections at related component and in-line harness connector terminal connections. Refer to (Refer to General Troubleshooting Procedures). Diagnostic Aids
5. Check for a broken (or partially broken) wire inside of the insulation which could cause system failure but prove "GOOD" in a continuity/voltage check. (Refer to General Troubleshooting Procedures).