Probing (Frontprobe & Backprobe)
After probing, when reconnecting connectors or replacing terminals, always be sure to reinstall Connector Position Assurance (CPA) and Terminal Position Assurance (TPA).
Frontprobe
When frontprobing of connectors is required, always use a mating terminal adapter from Connector Test Adapter Kit (J 35616-A). The use of proper adapters will ensure that proper terminal contact integrity is maintained. (refer to Procedures in Checking Terminal Contact).
Backprobe
Only backprobe connector terminals when specifically called for in diagnostic procedures. Since backprobing can be a source of damage to connector terminals, extra care must be taken to avoid deforming the terminal, either by forcing the test probe too far into the cavity or by using too large a test probe.
After backprobing any connector, always check for terminal damage. If terminal damage is suspected, check for proper terminal contact, refer to Checking Terminal Contact. Checking Terminal Contacts