Passenger Side
TEMPERATURE VALVE LINK ADJUSTMENT
Programmer Assembly:
1. Pull valve link from retainer on temperature valve.
2. Start vehicle, set temperature to 32°C (90°F).
3. Allow 45 seconds minimum for air mix valve actuator to move output crank to its full hot position. Move temperature valve to its full hot position and snap valve link into retainer on temperature valve.