Charge Indicator
The charging system data is received from the Powertrain Control Module
(PCM) via the class II serial data line. The instrument cluster will illuminate the charge indicator during bulb test and when the PCM has determined that an undervoltage
(11.2 volts) or overvoltage
(16.5 volts) condition exists. For more information, refer to
Starting and Charging System.
Starting and Charging