Door Lock/Unlock Switch Circuits
The front power door lock switches provide the input signals to the MALL module at the following two terminals of connector C2:- Terminal C6
- Terminal C7
Pressing a front power door lock switch to the LOCK position connects CKT 780 (RED/BLK) through the switch to ground CKT 1250. CKT 780 grounds the MALL module connector C2 terminal C7 in order to provide the door lock input signal. Pressing a front power door lock switch to the UNLOCK position provides a ground input signal in the same way to the MALL module on CKT 781 (ORN/BLK) at connector C2 terminal C6.