Upper or Mid
When the driver selects the UPPER mode, the blower motor turns ON. The driver may manually adjust the blower speed.The vacuum actuators move to the following positions:
^ The heater and A/C programmer supplies vacuum to the defrost-A/C valve.
^ The heater and A/C programmer supplies vacuum to one side of the heater-A/C-bi-level valve.
^ The air-inlet valve vents in the outside air position.
^ The defrost-A/C valve vents in the A/C position.
^ The heater-A/C-bi-level valve vents in the A/C position.
The blower pulls outside air into the system. The air is heated or cooled. The air is them forced through the instrument panel outlets.
The heater and A/C programmer energizes the air mix actuator in order to perform the following functions:
1. Determine the proper air discharge temperatures
2. Position the air mix valves accordingly