Hazard Lamps

Battery positive voltage (B+) is supplied at all times from the IR fuse block BRK/HZRD LPS fuse 6B via 140 (ORN). The current flows through the hazard flasher to the normally open switch in the turn/hazard switch. With the hazard switch in the ON position, battery positive voltage (B+) is applied through the turn/hazard switch to all four paths used by the left and right turn lamps. The following components flash on and off:
^ All turn lamps
^ Both indicators

With the hazard switch in the ON position, the turn circuit is always open, and the hazard flasher controls the lamps.