Operation CHARM: Car repair manuals for everyone.

LH Front Power Window Switch Operation

Battery voltage is applied to the POWER WDO/SUNROOF RELAY coil in the IP junction block from CKT 43 under the following conditions:
- The ignition switch is in the ACCY position.
- The ignition switch is in the RUN position.
- During the retaining accessory power (RAP).

The relay is permanently grounded on the coil side. Battery voltage is applied to the LH front power window switch under the following conditions:
- The coil is energized.
- The switch is closed.

Battery voltage is applied to the window motor when any UP switch in the LH front power window switch not associated with the express down is operated. The window motor is grounded through the DOWN contact of the LH front power window switch. The motor runs in order to drive the window up. Battery voltage is applied to the window motor in the opposite direction when any DOWN switch in the LH front power window switch is operated. The window motor is grounded through the UP contact in the LH front power window switch. The motor runs in order to drive the window down.