HVAC System - Automatic
REMOVAL PROCEDURE
1. Remove the right sound insulator.
2. Disconnect the electrical connector.
3. Remove the [1][2]blower control module retaining screws.
4. Remove the [1][2]blower control module (1).
INSTALLATION PROCEDURE
1. Install the [1][2]blower control module (1).
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the retaining screws.
Tighten
Tighten the bolt to 2 N.m (23 lb in).
3. Connect the electrical connector.
4. Install the right sound insulator.