B1369
CIRCUIT DESCRIPTIONThe instrument panel cluster (IPC) monitors the ignition 0 voltage circuit when the ignition switch is in either the ON position or the OFF position. If the IPC senses that the ignition 0 voltage circuit is low for greater than 3 seconds, DTC B1369 is set.
CONDITIONS FOR RUNNING THE DTC
^ The ignition switch is ON.
^ At least 3 seconds has elapsed since the ignition switch was cycled ON.
CONDITIONS FOR SETTING THE DTC
The ignition 0 input is low during power up or while in RUN for greater than 3 seconds.
ACTION TAKEN WHEN THE DTC SETS
^ The IPC stores DTC B1369 in memory.
^ The IPC will store conditions which were present when the DTC set as Failure Records data only. The information will not be stored as Freeze Frame data.
CONDITIONS FOR CLEARING THE DTC
^ A current DTC B1369 will clear when the malfunction is no longer present and the ignition switch is cycled.
^ A history DTC B1369 will be cleared after 100 ignition cycles with no current codes active during the 100 ignition cycles.
^ The IPC receives the clear code command from the scan tool.
DIAGNOSTIC AIDS
If the DTC is a history DTC, the problem may be intermittent. Refer to Testing for Intermittent and Poor Connections in Diagnostic Aids.
TEST DESCRIPTION
Steps 1-6:
The number below refers to the step number on the diagnostic table.
3. This step determines if the ignition 0 voltage circuit is open or shorted to ground.