Air Speed
The HVAC control assembly applies voltage to the blower motor control circuit that corresponds to the selected blower speed. The resistors and the blower motor are in a series circuit. The following list represents the number of resistors in series with the blower motor per particular speed request:^ Low speed-4 resistors
^ Medium 1 speed-3 resistors
^ Medium 2 speed-2 resistors
^ Medium 3 speed-1 resistor
When the operator requests High speed, the HVAC control assembly applies voltage to the blower motor relay through the high blower motor control circuit. The voltage energizes the blower motor relay, connecting the blower motor to battery positive voltage.
Off Mode
When the OFF position is selected, the HVAC control module applies voltage to the blower switch off input within the HVAC control module through the off blower motor control circuit. When the HVAC control module receives this input, any A/C request will be cancelled and the A/C request LED will turn off. Fresh air will still be brought in from the outside, but the LED indicator will not illuminate.