HVAC Control Module Programming and Setup
HVAC System Control Module Programming and Setup
Each of the following service procedures may require programming or setup procedures to be performed on the HVAC control module or HVAC actuators.
HVAC Control Module Replacement
If the HVAC manual or HVAC automatic control modules are replaced, an automatic re-calibration of all the actuators will occur. For the best re-calibration results, start and run the engine for at least one minute after installing the new module. Do not adjust any controls on the HVAC control module during the re-calibration procedure. If interrupted, improper HVAC performance may result. No additional procedures are necessary.
HVAC Control Module Reprogramming
Do not reprogram the HVAC control module unless directed by a service procedure or a service bulletin.
Reprogram HVAC Control Module-Refer to Service Programming System (SPS) (Programming and Relearning).
Actuator Replacement
If an actuator is replaced, the following procedure must be performed.
Re-Calibrating Actuators-Refer to Actuator Recalibration (Programming and Relearning) for the manual system.
Re-Calibrating Actuators-Refer to Actuator Recalibration (Programming and Relearning) for the automatic system.