Testing For Short to Voltage

TESTING FOR A SHORT TO VOLTAGE

NOTE: Refer to Test Probe Note in Service Precautions.

The following procedure tests for a short to Voltage in a circuit.
1. Set the rotary dial of the DMM to the V (DC) position.
2. Connect the positive lead of the DMM to 1 end of the circuit to be tested.
3. Connect the negative lead of the DMM to a good ground.
4. Turn ON the ignition and operate all accessories.
5. If the Voltage measured is greater than 1 volt, there is a short to Voltage in the circuit.