Refrigerant Oil: Service and Repair
OIL CHARGE-COMPONENT REPLACEMENT
When replacing certain components of an air conditioning system an oil charge must be added to the system to keep the proper level of refrigerant oil in the system.
If there are no signs of excessive leakage, add the following amount of oil depending on component to be replaced.
Evaporator 3 ounces
Condenser 1 ounce
If accumulator or compressor are to be replaced, drain oil from component to be replaced and measure, then add same amount of new oil to replacement component plus one additional ounce.
If the refrigerant charge is abruptly lost due to a large refrigerant leak, approximately three ounces of refrigerant oil will be carried out of the system with the refrigerant.
Upon replacement of a component which caused a large refrigerant leak, add three ounces of oil to the system plus the amount required for the component replaced.