S062
CODE S062 LR ROTARY SENSOR POSITION SIGNAL FAULTTEST CONDITIONS:
The RSS control module monitors the RS data for a sensor out-of-range condition. The signal is out-of-range if it is under voltage (0.35 V) or over voltage (4.75 V).
FAULT CONDITIONS:
If the signal is out-of-range for more than I second, the fault is detected.
ACTION TAKEN:
Set code, tum on "SERVICE RIDE CONTROL" message, and command all four dampers to firm.
DESCRIPTION:
The RSS control module monitors the RS data for a sensor out-of-range condition. The signal is out of range if it is under voltage (0.35 V) or over voltage (4.75 V). If the signal is out-of-range for more than 1 second, the fault is detected.
NOTES ON FAULT TREE:
[1] Refer to notes on intermittents. To diagnose this condition:
^ Clear codes,
^ Enter output cycling,
^ Manipulate affected wiring,
^ Shake and/or tap the sensor, and
^ Recheck for codes.
[2] The RS position signal fault code may set due to the corresponding RS over-current code being set. If this is the case, the over-current code must be diagnosed first.
[3] After replacing the rotary sensor always perform the trim height adjustment.
[4] Refer to clearing codes.
IMPORTANT:
^ DO NOT BACKPROBE SENSORS, DAMPERS, OR ELC / RSS CONNECTORS.
^ WHEN ALL DIAGNOSIS AND REPAIRS ARE COMPLETE, CLEAR CODES AND VERIFY OPERATION.