Operation CHARM: Car repair manuals for everyone.

LH Front Window Switch Operation

Battery voltage is applied from the WINDOWS circuit breaker through CKT 42 (RED) to the accessory time delay relay. When the ignition is in RUN or Retained Accessory Power (RAP) is active, the accessory time delay relay supplies voltage through CKT 70 (PNK) to the LH front power window switch. When an UP switch on the LH front power window switch is operated, battery voltage is applied to the power window motor. The power window motor is grounded through the DOWN contacts of the LH front power window switch to ground G204. The motor runs to drive the power window up. When a DOWN switch in the LH front power window switch is operated, battery voltage is applied to the power window motor in the opposite direction. The power window motor is grounded through the UP contacts in the LH front power window switch to ground G204. The motor runs to drive the power window down.