HO2S Bank 1 Sensor 1
The scan tool range is
0-1275 mV (0-1.275 volts). This parameter indicates the output voltage for Heated Oxygen Sensor
(HO2S) bank 1 sensor 1 (rear bank fuel control
oxygen sensor). The voltage should fluctuate constantly within a range between about
50 mV (lean exhaust) and
800 mV (rich exhaust) while operating in Closed Loop.