Generator Cooling Pipe/Hose Quick Connect Fitting
Generator Cooling Pipe/Hose Quick Connect Fitting
Tools Required
J 41623-B Cooler Quick Connect Tool
Removal Procedure
1. Install the J 41623-B onto the generator cooling inlet pipe.
2. Slide the J 41623-B toward the generator cooling inlet pipe fitting.
Important: Rotate the J 41623-B to engage the generator cooling inlet pipe fitting's retainer slots.
The J 41623-B should be nearly flush with the fitting.
3. Connect the J 41623-B onto the generator cooling inlet pipe fitting.
4. Rotate the J 41623-B until the retainer clip (1) rises above the fitting retainer seat.
5. Pull back on the generator cooling inlet pipe to disengage the pipe from the generator cooling inlet pipe fitting.
6. Remove the J 41623-B from the generator cooling inlet pipe.
Installation Procedure
Important: Inspect the generator cooling inlet pipe fitting and retaining clip for signs of wear or damage. Replace the components if necessary.
1. Install the generator cooling inlet pipe into the generator cooling inlet pipe fitting.
A distinct snap should be heard or felt when assembling the generator cooling inlet pipe to the fitting.
2. To ensure the cooler line is properly installed, give the cooler pipe a gentle pull.