Operation CHARM: Car repair manuals for everyone.

Camshaft Position Actuator Solenoid Valve Replacement




Camshaft Position Actuator Solenoid Valve Replacement

Special Tools

J 45059 Angle Meter

Removal Procedure




1. Remove the camshaft position (CMP) actuator magnet. Refer to Camshaft Position Actuator Magnet Replacement (Camshaft Position Actuator Magnet Replacement).
2. Remove and discard the CMP actuator solenoid valve.

Installation Procedure




1. Install the a NEW CMP actuator solenoid valve until snug.
With the CMP actuator properly positioned onto the camshaft, the CMP actuator solenoid valve can be threaded completely into the camshaft using light hand pressure. Tighten by hand until snug.

Caution: Refer to Fastener Caution (Fastener Caution).

2. Tighten the CMP actuator solenoid valve.

1. Tighten the solenoid valve a first pass to 65 Nm(48 lb ft).
2. Tighten the solenoid valve a final pass and additional 90 degrees using J 45059 .

3. Install the CMP actuator magnet. Refer to Camshaft Position Actuator Magnet Replacement (Camshaft Position Actuator Magnet Replacement).