175 Amp Mega Fuse Replacement




175 Amp Mega Fuse Replacement

Removal Procedure




1. Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (Service and Repair).
2. Remove the fuse cover.




3. Remove the starter solenoid cable nut (1) from the fuse stud.
4. Remove the starter solenoid cable terminal (2) from the fuse stud.




5. Remove the generator battery jumper cable to fuse nut (3).
6. Remove the generator battery jumper cable terminal (4) from the fuse stud.
7. Remove the positive battery cable terminal from the fuse stud.




8. Remove the fuse from the holder.

Installation Procedure




1. Install the fuse to the holder.




2. Install the positive battery cable terminal to the fuse stud.
3. Install the generator battery jumper cable terminal (4) to the fuse stud.

Caution: Refer to Fastener Caution (Fastener Caution).

4. Install the generator battery jumper cable to fuse nut (3).

Tighten the nut to 15 Nm(11 lb ft).




5. Install the starter solenoid cable terminal (2) to the fuse stud.
6. Install the starter solenoid cable nut (1) to the fuse stud.

Tighten the nut to 15 Nm(11 lb ft).




7. Install the fuse cover.