Mode Door Replacement - Lower
Mode Door Replacement - Lower
Removal Procedure
1. Remove the HVAC module. Refer to HVAC Module Assembly Replacement (Non-HP2) (Service and Repair)HVAC Module Assembly Replacement (HP2) (Service and Repair).
2. If equipped remove the heat stakes (1) from the HVAC module (2) with a screwdriver and a hammer.
3. If equipped remove the HVAC module assembly screws.
4. Separate the HVAC module assembly.
5. Remove the air temperature separator plate (5) from the HVAC module assembly (10).
6. Remove the lower mode door (9) from the HVAC module assembly (10).
Installation Procedure
1. Install the lower mode door (9) to the HVAC module assembly (10).
2. Install the air temperature separator plate (5) to the HVAC module assembly (10).
3. Install the HVAC module assembly halves.
Caution: Refer to Fastener Caution (Fastener Caution).
Note: For every heat stake removed ensure that you install a screw.
4. Install the screws to the HVAC module assembly.
Tighten the screws to 1.6 Nm(14 lb in).
5. Install the HVAC module. Refer to HVAC Module Assembly Replacement (Non-HP2) (Service and Repair)HVAC Module Assembly Replacement (HP2) (Service and Repair).