Column Shift
Description:
1. Position transmission lever B clockwise to forward detent, then turn ignition switch to "LOCK."
2. Remove column lash by rotating lever J downward and tightening bolt C.
3. Turn ignition switch to "UNLOCK", then position transmission levers in Neutral To position levers in Neutral, move levers B and E to forward detent, then turn counterclockwise one detent.
4. Align gage pin holes in levers H, J and K, then insert gage pin.
5. Repeat Step 2 for rod F and levers E and H.
6. Remove gage pin.