Power Requirements
Operating current at the CCM's battery terminals should not exceed 1.0 amp while the CCM is awake; 200 milliamps is an approximately "normal" value. This may be higher if Delayed Accessory Bus (DAB) is active. The Delayed Accessory Bus system allows operation of the Audio System and/or power windows until a door is opened or 15 minutes passes. When the CCM is asleep, the current should not exceed 15 milliamps. Operating current drawn by the IGN 1 and IGN 3 terminals of the CCM should not exceed 100 milliamps each.For most CCM functions, the CCM will operate properly with a system voltage of 9-16 volts.