Operation CHARM: Car repair manuals for everyone.

Negative Backpressure EGR Valve With Solenoid


EGR Solenoid Circuit (Typical):






PURPOSE
To provide electrical control of the Exhaust Gas Recirculation (EGR) valve.

OPERATION
To regulate EGR flow, the control module operates a solenoid to control the EGR valve. This solenoid is normally closed. By providing a ground path, the control module energizes the solenoid which then allows vacuum to pass to the EGR valve.

The control module monitors EGR effectiveness by de-energizing the EGR control solenoid, which prevents vacuum flow to the EGR valve. With the EGR valve closed and oxygen sensor cycling normally, fuel integrator counts will be greater than they were during normal EGR operation. If the change is not within the calibrated window, a Code 32 will be set.

The control module will check EGR operation when:
- Engine speed is above 2000 rpm.
- Engine vacuum is between 8 and 30 kPa.
- No change in throttle position while test is being run.