Operation CHARM: Car repair manuals for everyone.

Compressor Control Valve Assembly: Description and Operation

The compressor is equipped with a pressure relief valve which is placed in the system as a safety factor. Under certain conditions, the refrigerant on the discharge side may exceed the designed operating pressure. To prevent system damage, the valve is designed to open automatically at approximately 3036 kPa (440 psi). Any condition that causes this valve to open should be corrected, and the refrigerant oil should be replaced as necessary. The air conditioning refrigerant pressure sensor should also be checked for proper calibration.