Control Module HVAC: Service and Repair
BLOWER CONTROL MODULE REPLACEMENTREMOVAL PROCEDURE
1. Remove the IP lower insulator panel - RH. Refer to Closeout/insulator Panel Replacement IP Lower (LH) or Closeout/insulator Panel Replacement - IP Lower (RH) in Instrument Panel, Gauges and Console.
2. Disconnect the blower motor control module electrical connector.
3. Disconnect the blower motor control module electrical connector.
4. LOOSEN the blower motor control module forward two retaining screws (nearest the dash mat) approximately 5 mm (0.197 in).
(The resistor is slotted at the forward retaining locations.)
5. Remove the control module rear retaining screw.
6. Tilt down the rear of the control module.
7. Remove the blower motor control module from the vehicle.
INSTALLATION PROCEDURE
1. Position the blower motor control module forward retaining slots onto the forward retaining screws.
2. Align and seat the control module to the HVAC module.
3. Install the control module rear retaining screw.
NOTE: Refer to Fastener Notice in Service Precautions.
4. Tighten all the blower motor control module retaining screws.
Tighten
Tighten the blower motor control module retaining screws to 1.6 N.m (14 lb in).
5. Connect the blower motor control module electrical connector to the blower motor.
6. Connect the blower motor control module electrical connector.
7. Install the IP lower insulator panel - RH. Refer to Closeout/insulator Panel Replacement - IP Lower (LH) or Closeout/Insulator Panel Replacement - IP Lower (RH) in Instrument Panel, Gauges and Console.