Operation CHARM: Car repair manuals for everyone.

HO2S 1

The scan tool range is 0 to 1132 mV. This parameter represents the fuel control exhaust oxygen sensor output voltage. Should fluctuate constantly within a range between 10 mV, lean exhaust, and 1000 mV, rich exhaust, while operating in closed loop.