EGR Learned Minimum Position
The scan tool range is
0-5 volts. Represents the learned voltage that the
PCM uses to determine whether or not the
EGR valve is fully closed (
0 percent pintle position). If the desired
EGR position is
0 percent and a difference of more than
0.4 volt between EGR feedback and EGR closed valve pintle position is detected, DTC P1406 will set.