B0090
CIRCUIT DESCRIPTIONWhen the ignition is turned ON, the Inflatable Restraint Sensing And Diagnostic Module (SDM) performs tests to diagnose critical malfunctions within the SIR system. The SDM monitors the IP module disable switch-signal and IP module disable switch indicator- control circuits in order to determine whether or not to disable the inflatable restraint IP module. The SDM also monitors the IP module disable switch-signal and the IP module disable switch indicator- control circuits for an open, high resistance, short to ground or short to voltage condition.
CONDITIONS FOR RUNNING THE DTC
Ignition 1 voltage is within the normal operating voltage range.
CONDITIONS FOR SETTING THE DTC
^ The IP module disable switch must be in the ON position.
^ The voltage detected in the IP module disable switch indicator-control and the IP module disable switch-signal circuits is less than 1 volt.
^ The voltage detected in the IP module disable switch indicator-control and the IP module disable switch-signal circuits is greater than 1 volt.
ACTION TAKEN WHEN THE DTC SETS
^ The SDM defaults to the OFF position, diabling the IP module.
^ The SDM attempts to turn the inflatable restraint IP module disable switch ON.
^ The SDM commands the AIR BAG indicator ON via Class 2 serial data.
CONDITIONS FOR CLEARING THE DTC
^ The condition responsible for setting the DTC no longer exists and the scan tool Clear DTCs function is used.
^ A history DTC will clear once 255 malfunction free ignition cycles have occurred.
DIAGNOSTIC AIDS
Thoroughly inspect the wiring and the connectors. An incomplete inspection of the wiring and the connectors may result in misdiagnosis, causing a part replacement with the reappearance of the malfunction. The following are possible causes of the malfunction:
^ A short to ground or a short to voltage in the IP module disable switch-signal circuit
^ A short to ground or a short to voltage in the IP module disable switch indicator-control circuit
^ Damage or corrosion on the IP module disable switch harness connector
^ Damage or corrosion on the IP module disable switch indicator harness connector
^ Damage or corrosion on the SDM harness connector
^ An internal IP module disable switch malfunction
^ An internal IP module disable switch indicator malfunction
^ An internal SDM malfunction
If an intermittent condition exists, refer to Diagnostic Aids for Circuit Testing and Wiring Repair procedures.
TEST DESCRIPTION
Steps 1-10:
Steps 11-14:
The numbers below refer to the step numbers on the diagnostic table:
6. This step tests to see if there is an open or high resistance in the IP module disable switch.
9. This step tests to see if there is a short to ground or a short to voltage in the IP module disable switch-signal circuit.
10. This step tests to see if there is a short to ground or a short to voltage in the IP module disable switch indicator-control circuit.